超聲波流量計生產(chǎn)公司 0411-87305712

            超聲波流量計實時信息,超聲波流量計資料下載,超聲波流量計價格,相信大連索尼卡—流量測量問題輕松解決。

            « 什么是防護等級IP65,IP55Handheld Ultrasonic Flowmeter »

            Ultrasonic flowmeter

            Ultrasonic flowmeter   Features
            • Guaranteed lowest price on the market
            • High accuracy: ±1% normally; ±0.5% when on-site calibration available
            • Wide pipe size range (from 1" to 240")
            • Non-intrusive. No pipe disturbance. No moving parts. No pressure drop.
            • Easy and economical installation. No pipe cutting or hole drilling.
            • Easy to use and set up. Self-explanatory menu programming
            • Velocity, volumetric and totalized flow
            • IP65 weather-proof enclosure
            • 4-20mA output, OCT digital output, relay output, batch control, alarm control
            • Isolated RS485 interface, MODBUS compatible
            • Optional GPRS / GSM networking module
            • No maintenance
            • Low power consumption. Less than 1 W
            • Ideal for both clean and opaque liquid flows
               
            Descriptions :
            The FV2000 General Purpose Wall-Mount Clamp-on Ultrasonic Flowmeter is the first member of the 3rd generation ultrasonic flowmeters from sonic. Compared with the predecessors, the 3rd generation ultrasonic flowmeters offer better performances and a richer feature set, all at a lower price.
            The FV2000 is designed to be installed at a fixed location for long-term flow measurement from outside of a pipe that carries pure liquids and liquids with minor suspended particles. It utilizes cutting-edge technologies such as advanced transducer design, low voltage transmission, digital signal processing, and self adaptation to achieve high performance.
            As QUALITY is of crucial importance, all transducers are carefully paired, and all flowmeters are wet-calibrated in the factory to further ensure system accuracy and reliability.
            FV2000  provides versatile input/output interfaces, such as digital and relay outputs, batch control, alarm, flow totalizing, 4-20mA output, and optional RTD interface for thermal energy measurement, which can be easily used by a host computer or a flow controller for process monitoring and control. Besides, the isolated built-in RS-485 port and the optional GPRS/GSM module make remote flow monitoring easy and reliable.
            Due to the non-intrusive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, no pressure dependency and no blockage on the flow. The installation is very simple and requires no special skills or tools. The cost of installation, operation, and maintenance is lower than that of conventional flowmeters.
            FV2000 is an ideal choice for demanding applications where low-cost, high-performance and non-intrusiveness are a must. A pplications include, but are not limited to, liquid process control, water flow measurement (hot/chill water, city water, sea wat beverages, and many other liquids.
               

             
            Main Unit
            Repeatability
            Better than  ±0.5%
            Accuracy
            Better than ±1%. Can reach ±0.5 when on-situ calibration is available
            Response Time
            0.5s. 0-99s user-programmable
            Velocity
             -52ft/s - +52 ft/s (-16m/s - +16 m/s), bi-directional.
            Display
            LCD with backlight.  2 x 20 character display.
            Displays instantaneous flow rate, totalized flow rate, velocity, sound speed, time, analog inputs, etc.
            Units
            English (U.S.) or metric
            Signal Outputs
            Current output: 4-20mA or 0-20mA. Impedance 0-1k. Accuracy 0.1%
            Isolated OCT output: can be programmed as pulse output for flow totalizers or frequency output for flow rate
            Relay: can be programmed  to control alarm, valve or batch process
            Sound alarm
            Signal Inputs
            One channel 4-20mA current input: for signals such as temperature, pressure, liquid level. etc. Accuracy 0.1%. Additional analog input channels are available upon request
            Two RTD temperature channels (refer to model STUF-300R1B): to accommodate two PT100 temperature sensors. Thermal energy measurement and calculation functionalities implemented.
            Recording
            Automatically records the following information:1) The totalizer data of the last 64 days / 64 months / 64 years;2) The power time and corresponding flow rate of the last 64 power-on and -off events; 3) Allows for manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days.
            Communication Interface
            Isolated RS-485. Supports the MODBUS protocol. Optional GPRS / GSM module for networking, remote monitoring and remote control (for model STUF-300FNB only)
            Enclosure
            Protection Class:  IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model STUF-300F2B only)
            Liquids
            Liquid Types
            Virtually all commonly used liquids (full pipe)
            Liquid Temp
            -40?F ~ 312?F (-40?C ~ 155?C), depending on transducer type
            Suspension concentration
            < 20,000ppm. Particle or air bubble size should not exceed 75um
            Pipe
            Pipe Size
            1" ~ 240"For pipe size of 1” and smaller, the STUF-300FxG flow-cell flowmeter is recommended
            Pipe Material
            All metals, most plastics, fiber glass, etc.  Allows for pipe liner.
            Pipe Straight Run
             15D or longer preferred, where D is pipe diameter.
            If a pump or valve is near upstream, the straight pipe section should be > 30D.
            Cable
            Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines. Neither should it be close to strong interference sources such as power transformers.
            Environment
            Temperature
            Main unit: 0?F - 176?F (-30?C - 80?C)
            Transducer: -40?F ~ 212?F (-40?C ~ 100?C) for the standard version; -40?F ~ 312?F (-40?C ~ 155?C) for the higher temperature version
            Humidity
            Main unit: 85% RH
            Transducer: water-immersible, water depth less than 10’ (3m)
            Power
            AC: 90V / 260V, or, DC: 18VDC-36VDC<1 Watt
            Weight
            Standard main unit: 4 lb (2 kg),   Network main unit: 5 lb (2.5 kg)
               
            Transducer Options:
             
            Clamp On Flow Meters
            Type S1
            Small size transducer (magnetic) for pipe size 1” – 4” (DN25 – DN100mm) Note: for pipes of 1” and below, we recommend our flow-cell transducer (Stuf-300FxG.)
            High-temp transducer Type S1HT
            Small size transducer
            high temperature (up to 155°C) for pipe size 1” – 4” (DN25 – DN100mm)  
            Digital Flow Meters
            Type M1
            Medium size transducer (magnetic) for pipe size 2” – 28” (DN50 – DN700mm)
            clamp-on transit-time ultrasonic flowmeter
            Type M1HT Medium size transducer
            high temperature (up to 155°C) for pipe size 2” – 28” (DN50 – DN700mm)  
            Clamp on Ultrasonic Flow Meters
            Type L1 Large size transducer (magnetic) for pipe size 11” – 240” (DN300 – DN6,000mm) 